High Efficiency Water Softener

high efficiency water softenerThis particular compilation of volume-controlled Counter Current Water Softening plants are chosen especially for dependable as well as cost-effective operation.

The benefit of using volume controlled water softeners is the softening resins are used to their total and entire capacity prior to the automated regeneration occurring.

The particular models are made as entirely automated duty as well as standby models offering 100% duty Twenty four hours every day.

The benefit of the water softener using Counter Current is that the service and regeneration flows are within opposing directions and thatt that salt usage will be minimised,

water condition can easily be managed in between regenerations and water consumption is generally decreased by as much as 80% in comparison with any traditional water softener.

Plant configuration will be versatile to match the plant location offered and also the plant is actually operated by way of an on board PLC whereby the softeners performance can easily be monitored.

Options:

Conductivity sensing throughout regeneration.
Simply by the installation of a conductivity meter to observe the rinse stages, water wastage is often decreased by 25-35 Percent.
The actual conductivity meter can calculate the softener rinse water value and can stop the actual rinse out routine whenever the conductivity meter reads a pre set amount, typically established at worst case inlet water quality.

Hardness Monitoring - In order to determine the caliber of the soft water a Testomat water hardness monitor is used. This could be set in place in order to trigger and alarm in the event the water hardness elevating over a pre set value. Additionally the actual read out at the monitor indicate the hardness of the water softener outlet stream within the standard display control panel.

Technical Data

Quantity-controlled/Duplex HVD 300 HVD 450 HVD 650 HVD 900 HVD 1200
Max. flow rate, m3/h* 10/15 18/21 25/30 32/39 41/50
Pressure loss at max flow, bar 1.1/1.5 1.1/1.5 1.1/1.5 1.1/1.5 1.1/1.5
Capacity at 50ppm CaCo3, m3 300 446 652 906 1200
Capacity at 100ppm CaCo3, m3 151 223 327 453 600
Capacity at 200ppm CaCo3, m3 75 112 163 225 300
Capacity at 300ppm CaCo3, m3 50 75 110 150 200
Salt consumption per regeneration, kg. 24 36 52 72 96
Regeneration time, minutes 50 55 60 65 70
Temperature max., oC 35 35 35 35 35
Water Pressure max., bar 10 10 10 10 10
Pipe connection, DN 65 65 65 80 100
Outlet connection, DN 40 40 40 40 40
Plant height, mm 2450 2500 2550 2600 2650
Plant width, mm 2800 3000 3120 3550 4000
Plant depth, mm 1400 1500 1600 1800 1900
Salt tank height, mm 1550 1550 1550 1550 1550
Salt tank diameter, mm 1040 1040 1040 1040 1040
Content of salt tank, litres 1150 1150 1150 1150 1150
Consumption of water during regeneration, m3 0.8 1.1 1.6 2.2 3.0
Consumption of water during regeneration with conductivity meter, m3 0.5 0.7 1 1.4 1.9

*At 15oC, 3.0 bar pressure, inlet softening plant (Regenerated state).

In certain instances the capacity indicated below may need to be reduced based on the total hardness, iron content and other contaminants.